Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Ultrasound measurement of optic nerve sheath diameter pre- and post-lumbar puncture.

Schott CK, Hirzallah MI, Heyman R, Lesky DN, Brant EB, Callaway CW. Ultrasound measurement of optic nerve sheath diameter pre- and post-lumbar puncture. The ultrasound journal. 2020 May 13; 12(1):26.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

BACKGROUND: To test the hypothesis that optic nerve sheath diameter (ONSD) correlates with real-time changes in intracranial pressure, we performed ultrasound measurements of the ONSD in ambulatory patients undergoing elective lumbar puncture (LP). We conducted a prospective cohort study, including adult patients undergoing LP in a non-emergent setting. We measured ONSD perpendicular to the optic nerve at 3 mm behind the globe in both eyes in the traverse and sagittal planes, with the patient supine. The primary outcome was change in ONSD from pre-LP to post-LP. We calculated association of opening and closing LP pressures with changes in the pre- and post-LP ONSD measurements. RESULTS: The mean patient age was 49.0 years (SD = 37-61, range 19-67) with 21 females (72.4%) and 26 (89.7%) white American (not Hispanic or Latino). The average opening pressure and closing pressures were 20.4 cm and 13.5 cm with a difference of 6.9 cm, (95% CI 3.9-10.0 cm). Pressures between the participants with baseline ONSD measurement > 5 mm (average opening pressure = 21.3 cm) to those < 5 mm (20.2 cm) differed by 1.1 cm (95% CI - 5.7 to 8.0). Linear regression revealed no association between the sagittal, transverse, average, and change in ONSD measurements with the observed LP opening pressure, change in LP pressure, or volume of cerebral spinal fluid (CSF) drained. CONCLUSIONS: In this study of ambulatory patients undergoing rapid decreases in ICP via elective LP, we detected no acute changes in ultrasonographic measurement of the ONSD.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.