Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Hospitalist Perspectives of Available Tests to Monitor Volume Status in Patients With Heart Failure: A Qualitative Study.

Maw A, Ortiz-Lopez C, Morris M, Jones CD, Gee E, Tchernodrinski S, Kramer HR, Galen B, Dempsey A, Soni NJ. Hospitalist Perspectives of Available Tests to Monitor Volume Status in Patients With Heart Failure: A Qualitative Study. Cureus. 2020 Jun 26; 12(6):e8844.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

Acute decompensated heart failure is the leading admitting diagnosis in patients 65 years and older with more than 1 million hospitalizations per year in the US alone. Traditional tools to evaluate for and monitor volume status in patients with heart failure, including symptoms and physical exam findings, are known to have limited accuracy. In contrast, point of care lung ultrasound is a practical and evidenced-based tool for monitoring of volume status in patients with heart failure. However, few inpatient clinicians currently use this tool to monitor diuresis. We performed semi-structured interviews of 23 hospitalists practicing in five geographically diverse academic institutions in the US to better understand how hospitalists currently assess and monitor volume status in patients hospitalized with heart failure. We also explored their perceptions and attitudes toward adoption of lung ultrasound. Hospitalist participants reported poor reliability and confidence in the accuracy of traditional tools to monitor diuresis and expressed interest in learning or were already using lung ultrasound for this purpose. The time required for training and access to equipment that does not impede workflow were considered important barriers to its adoption by interviewees.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.