Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Limitations of dual-energy CT in the detection of monosodium urate deposition in dense liquid tophi and calcified tophi.

Ahn SJ, Zhang D, Levine BD, Dalbeth N, Pool B, Ranganath VK, Benhaim P, Nelson SD, Hsieh SS, FitzGerald JD. Limitations of dual-energy CT in the detection of monosodium urate deposition in dense liquid tophi and calcified tophi. Skeletal Radiology. 2021 Aug 1; 50(8):1667-1675.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

OBJECTIVE: Dual-energy CT (DECT) detection of monosodium urate (MSU) crystal deposition has demonstrated good sensitivity and specificity in patients with established gout. However, limitations have been reported with early disease and with low urate burden. We aimed to study the performance of DECT in the detection and quantification of MSU deposition in solid and liquid tophi. MATERIALS AND METHODS: Patient-derived solid and liquid tophi, suspensions of commercial synthetic, and in-house synthetic MSU crystals were prepared at varying concentrations. DECT was performed at 80 kVp and 150 kVp, and post-processed using Syngo Via gout software (Siemens) that color-coded urate and cortical bone as green and purple, respectively. DECT findings were correlated with ultrasound and microscopic findings. The protocol was reviewed by IRB and considered a non-human subject research. RESULTS: DECT did not detect urate deposition in either patient-derived liquid tophi or in-house synthetic crystals at any concentration. Lowering the post-processing minimum threshold increased the detection of in-house synthetic crystals but did not change the detection of patient-derived liquid tophi. Areas of calcium-rich purple color-coded regions, masking detection of urate, within the solid tophi and surrounding liquid tophi were noted on DECT. Histology showed co-presence of calcium along with MSU deposition in these. CONCLUSION: This study illustrates important limitations of DECT for liquid tophi due to subthreshold CT attenuation and for calcified tophi due to the obscuration of urate by calcium. Urate may be either undetectable or underestimated by DECT when these conditions are present.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.