Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Development and Evaluation of a Rules-based Algorithm for Primary Open-Angle Glaucoma in the VA Million Veteran Program.

Nealon CL, Halladay CW, Kinzy TG, Simpson P, Canania RL, Anthony SA, Roncone DP, Sawicki Rogers LR, Leber JN, Dougherty JM, Sullivan JM, Wu WC, Greenberg PB, Iyengar SK, Crawford DC, Peachey NS, Cooke Bailey JN, VA Million Veteran Program. Development and Evaluation of a Rules-based Algorithm for Primary Open-Angle Glaucoma in the VA Million Veteran Program. Ophthalmic Epidemiology. 2022 Dec 1; 29(6):640-648.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

The availability of electronic health record (EHR)-linked biobank data for research presents opportunities to better understand complex ocular diseases. Developing accurate computable phenotypes for ocular diseases for which gold standard diagnosis includes imaging remains inaccessible in most biobank-linked EHRs. The objective of this study was to develop and validate a computable phenotype to identify primary open-angle glaucoma (POAG) through accessing the Department of Veterans Affairs (VA) Computerized Patient Record System (CPRS) and Million Veteran Program (MVP) biobank. Accessing CPRS clinical ophthalmology data from VA Medical Center Eye Clinic (VAMCEC) patients, we developed and iteratively refined POAG case and control algorithms based on clinical, prescription, and structured diagnosis data (ICD-CM codes). Refinement was performed via detailed chart review, initially at a single VAMCEC (n  =  200) and validated at two additional VAMCECs (n  =  100 each). Positive and negative predictive values (PPV, NPV) were computed as the proportion of CPRS patients correctly classified with POAG or without POAG, respectively, by the algorithms, validated by ophthalmologists and optometrists with access to gold-standard clinical diagnosis data. The final algorithms performed better than previously reported approaches in assuring the accuracy and reproducibility of POAG classification (PPV > 83% and NPV > 97%) with consistent performance in Black or African American and in White Veterans. Applied to the MVP to identify cases and controls, genetic analysis of a known POAG-associated locus further validated the algorithms. We conclude that ours is a viable approach to use combined EHR-genetic data to study patients with complex diseases that require imaging confirmation.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.