Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Survival of Hydroxyapatite-Coated Versus Non-hydroxyapatite-Coated Total Hip Arthroplasty Implants in a Veteran Population.

Tyagi V, Harris AHS, Giori NJ. Survival of Hydroxyapatite-Coated Versus Non-hydroxyapatite-Coated Total Hip Arthroplasty Implants in a Veteran Population. The Journal of arthroplasty. 2022 Jun 1; 37(6):1143-1145.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

BACKGROUND: Hydroxyapatite (HA) coatings were introduced to improve uncemented implant osteointegration and to prevent loosening and osteolysis. However, data regarding these implants have been inconsistent. We studied the effect of HA coating of femoral stems and acetabular cups on component revision after primary total hip arthroplasty (THA) in the veteran population. METHODS: We identified patients who underwent uncemented primary THA at any Veterans Health Administration (VHA) hospital from 2000 to 2017 and who had implants that were available as either HA-coated or non-HA-coated models. The endpoint was removal of the component of interest for any reason. For each individual stem and shell, unadjusted and adjusted (for age and body mass index) Cox proportional hazards models were used to estimate hazard ratios for the risk of explantation between HA-coated and non-HA-coated implants of the same type. RESULTS: A total of 262 HA-coated cups, 4580 non-HA-coated cups, 4767 HA-coated stems, and 9397 non-HA-coated stems were available for analysis. The mean follow-up time was 9.01 years (43,627 total implant-years) for cups and 7.13 years (101,004 total implant-years) for stems. One of the two shells reviewed had significantly lower survivorship and an elevated hazard ratio for explantation with HA coating. Among the five implant pairs of stems, and the other shell, implant survival and hazard ratios for explantation were not affected by HA coating. CONCLUSION: HA coating did not improve THA implant survival in our veteran population. Although HA-coated versions of hip implants tend to be more costly than their noncoated counterparts, these results do not support their general use.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.