Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Insulin Pump Alarms During Adverse Events: A Qualitative Descriptive Study.

Estock JL, Codario RA, Zupa MF, Keddem S, Rodriguez KL. Insulin Pump Alarms During Adverse Events: A Qualitative Descriptive Study. Journal of Diabetes Science and Technology. 2023 Oct 31; 19322968231209999.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

OBJECTIVE: Explore alarm signals cited in insulin pump-associated adverse events (AEs), describe the clinical consequences and other root cause informing remarks that cooccurred with the alarm signals, and identify opportunities for improvements to patient education, instructional materials, and alarm systems to prevent future AEs. RESEARCH DESIGN AND METHODS: We explored the type, frequency, and associated clinical consequences of alarm signals cited in a pre-coded data set of 2294 insulin pump-associated AEs involving the MiniMed 670G, MiniMed 630G, and t:slim X2. We also explored the clinical consequences and other root cause informing remarks that cooccurred with the top 10 most frequently cited alarm signals. RESULTS: Overall, 403 AEs narratives cited at least one alarm signal. Of the 40 unique alarm signals cited, 42.5% were "alarms," 25.0% were "alerts," and 32.5% were not referenced in the instructional materials packaged with the corresponding pump. The top 10 most frequently cited alarm signals included two obstruction of flow alarms, which accounted for 49.9% of all AEs citing at least one alarm, and two unreferenced alarms. The most frequent cooccurring root cause informing remark varied across the top 10 alarm signals and revealed valuable insight into why these alarms may have occurred. CONCLUSIONS: Our findings demonstrate the value of analyzing alarm signals cited in insulin pump-associated AEs and reveal multiple opportunities for providers to educate patients on how to respond to alarm signals and manage their pumps to avoid AEs, and for insulin pump manufacturers to update instructional materials and improve alarm systems to support appropriate patient response.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.