Defibrillator implantations for primary prevention in the United States: Inappropriate care or inadequate documentation: Insights from the National Cardiovascular Data ICD Registry.

Kaiser DW, Tsai V, Heidenreich PA, Goldstein MK, Wang Y, Curtis J, Turakhia MP, National Cardiovascular Data Registry. Defibrillator implantations for primary prevention in the United States: Inappropriate care or inadequate documentation: Insights from the National Cardiovascular Data ICD Registry. Heart Rhythm. 2015 Oct 1; 12(10):2086-93.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

BACKGROUND: Prior studies have reported that more than 20% of implantable cardioverter-defibrillator (ICD) implantations in the United States do not adhere to trial-based criteria. OBJECTIVE: We sought to investigate the patient characteristics associated with not meeting the inclusion criteria of the clinical trials that have demonstrated the efficacy of primary prevention ICDs. METHODS: Using data from the National Cardiovascular Data Registry's ICD Registry, we identified patients who received ICDs for primary prevention from January 2006 to December 2008. We determined whether patients met the inclusion criteria of at least 1 of the 4 ICD primary prevention trials: Multicenter Automatic Defibrillator Implantation Trial (MADIT), MADIT-II, Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT), and the Multicenter Unsustained Tachycardia Trial (MUSTT). RESULTS: Among 150,264 patients, 86% met criteria for an ICD implantation based on trial data. The proportion of patients who did not meet trial-based criteria increased as age decreased. In multivariate analysis, the significant predictors for not meeting trial criteria included prior cardiac transplantation (odds ratio [OR] 2.1), pediatric electrophysiology operator (OR 2.0), and high-grade atrioventricular conduction disease (OR 1.4). CONCLUSION: Among National Cardiovascular Data Registry registrants receiving first-time ICDs for primary prevention, the majority met trial-based criteria. Multivariate analyses suggested that many patients who did not meet the trial-based criteria may have had clinical circumstances that warranted ICD implantation. These findings caution against the use of trial-based indications to determine site quality metrics that could penalize sites that care for younger patients. The planned incorporation of appropriate use criteria into the ICD registry may better characterize patient- and site-level quality and performance.