Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Application of Machine Learning Models to Biomedical and Information System Signals From Critically Ill Adults.

Lilly CM, Kirk D, Pessach IM, Lotun G, Chen O, Lipsky A, Lieder I, Celniker G, Cucchi EW, Blum JM. Application of Machine Learning Models to Biomedical and Information System Signals From Critically Ill Adults. Chest. 2023 Nov 1.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

BACKGROUND: Machine learning (ML)-derived notifications for impending episodes of hemodynamic instability and respiratory failure events are interesting because they can alert physicians in time to intervene before these complications occur. RESEARCH QUESTION: Do ML alerts, telemedicine system (TS)-generated alerts, or biomedical monitors (BMs) have superior performance for predicting episodes of intubation or administration of vasopressors? STUDY DESIGN AND METHODS: An ML algorithm was trained to predict intubation and vasopressor initiation events among critically ill adults. Its performance was compared with BM alarms and TS alerts. RESULTS: ML notifications were substantially more accurate and precise, with 50-fold lower alarm burden than TS alerts for predicting vasopressor initiation and intubation events. ML notifications of internal validation cohorts demonstrated similar performance for independent academic medical center external validation and COVID-19 cohorts. Characteristics were also measured for a control group of recent patients that validated event detection methods and compared TS alert and BM alarm performance. The TS test characteristics were substantially better, with 10-fold less alarm burden than BM alarms. The accuracy of ML alerts (0.87-0.94) was in the range of other clinically actionable tests; the accuracy of TS (0.28-0.53) and BM (0.019-0.028) alerts were not. Overall test performance (F scores) for ML notifications were more than fivefold higher than for TS alerts, which were higher than those of BM alarms. INTERPRETATION: ML-derived notifications for clinically actioned hemodynamic instability and respiratory failure events represent an advance because the magnitude of the differences of accuracy, precision, misclassification rate, and pre-event lead time is large enough to allow more proactive care and has markedly lower frequency and interruption of bedside physician work flows.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.