Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Usability Evaluation of a Community Pharmacy Health Information Exchange Interface Prototype.

Hettinger KN, Snyder ME, Adeoye-Olatunde OA, Russ-Jara AL. Usability Evaluation of a Community Pharmacy Health Information Exchange Interface Prototype. Applied clinical informatics. 2023 Aug 1; 14(4):811-821.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

OBJECTIVE: Few community pharmacies have access to health information exchange (HIE) data. We conducted a first-of-its-kind usability evaluation of an HIE interface prototype (referred to throughout as the "HIE-Pioneer mock-up") developed with pharmacists and pharmacy technicians to aid future implementation in community pharmacies. METHODS: Community pharmacists and pharmacy technicians were recruited to complete usability evaluations with the HIE-Pioneer mock-up. Each usability evaluation lasted up to 60?minutes. System usability scale (SUS) scores were collected from each participant following each usability evaluation session and summarized with descriptive statistics. Usability evaluation videos were reviewed for common usability attributes, such as the impact of identified usability problems, learnability, and efficiency. Time on task, task success rates, and prototype utilization were also recorded. RESULTS: Sixteen total participants completed usability testing across three community pharmacies. The average SUS score was 69.7 (scale 0-100, where 100 is the best), with pharmacists on average reporting higher satisfaction than technicians (74.1 vs. 65.3, respectively). Altogether, we identified 23 distinct usability problems. Key problems identified included needed clarification in tool label names and accessibility of HIE links within the existing workflow. Overall, the usability of the HIE-Pioneer mock-up generally fostered pharmacy professionals'' ease of learning and efficiency. CONCLUSION: Our study identified key areas, and potential solutions, to improve the usability of the HIE-Pioneer mock-up. Overall, pharmacy professionals viewed the HIE-Pioneer mock-up positively, with good satisfaction ratings. The HIE-Pioneer mock-up provides a blueprint for future HIE implementation in community pharmacy settings, which would increase community pharmacy teams'' access to HIE data nationwide. Community pharmacy access to bi-directional HIE is expected to improve communication among more health care professionals involved in patient care and equip pharmacy professionals with needed information for improved clinical decision-making.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.