Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Physical performance measures in the clinical setting.

Studenski S, Perera S, Wallace D, Chandler JM, Duncan PW, Rooney E, Fox M, Guralnik JM. Physical performance measures in the clinical setting. Journal of the American Geriatrics Society. 2003 Mar 1; 51(3):314-22.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

OBJECTIVES: To assess the ability of gait speed alone and a three-item lower extremity performance battery to predict 12-month rates of hospitalization, decline in health, and decline in function in primary care settings serving older adults. DESIGN: Prospective cohort study. SETTING: Primary care programs of a Medicare health maintenance organization (HMO) and Veterans Affairs (VA) system. PARTICIPANTS: Four hundred eighty-seven persons aged 65 and older. MEASUREMENTS: Lower extremity performance Established Population for Epidemiologic Studies of the Elderly (EPESE) battery including gait speed, chair stands, and tandem balance tests; demographics; health care use; health status; functional status; probability of repeated admission scale (Pra); and primary physician's hospitalization risk estimate. RESULTS: Veterans had poorer health and higher use than HMO members. Gait speed alone and the EPESE battery predicted hospitalization; 41% (21/51) of slow walkers (gait speed < 0.6 m/s) were hospitalized at least once, compared with 26% (70/266) of intermediate walkers (0.6-1.0 m/s) and 11% (15/136) of fast walkers ( > 1.0 m/s) (P < .0001). The relationship was stronger in the HMO than in the VA. Both performance measures remained independent predictors after accounting for Pra. The EPESE battery was superior to gait speed when both Pra and primary physician's risk estimate were included. Both performance measures predicted decline in function and health status in both health systems. Performance measures, alone or in combination with self-report measures, were more able to predict outcomes than self-report alone. CONCLUSION: Gait speed and a physical performance battery are brief, quantitative estimates of future risk for hospitalization and decline in health and function in clinical populations of older adults. Physical performance measures might serve as easily accessible "vital signs" to screen older adults in clinical settings.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.