Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Exploring inappropriate certified nursing assistant glove use in long-term care.

Burdsall DP, Gardner SE, Cox T, Schweizer M, Culp KR, Steelman VM, Herwaldt LA. Exploring inappropriate certified nursing assistant glove use in long-term care. American journal of infection control. 2017 Sep 1; 45(9):940-945.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

BACKGROUND: Certified Nursing Assistants (CNAs) frequently wear gloves when they care for patients in standard precautions. If CNAs use gloves inappropriately, they may spread pathogens to patients and the environment, potentially leading to health care-associated infections (HAIs). METHODS: Using a descriptive structured observational design, we examined the degree of inappropriate health care personnel glove use in a random sample of 74 CNAs performing toileting and perineal care at 1 long-term care facility. RESULTS: During the 74 patient care events, CNAs wore gloves for 80.2% (1,774/2,213) of the touch points, failing to change gloves at 66.4% (225/339) of glove change points. CNAs changed gloves a median of 2.0 times per patient care event. A median of 1.0 change occurred at a change point. CNAs failed to change their gloves at a glove change point a median of 2.5 times per patient care event. Most (61/74; 82.4%) patient care events had > 1 contaminated touch point. Over 44% (782/1,774) of the gloved touch points were defined as contaminated for a median of 8.0 contaminated glove touch points per patient care event. All contaminated touches were with gloved hands (P? < .001). CONCLUSIONS: Inappropriate glove use was frequently observed in this study. Contaminated gloves may be a significant cause of cross-contamination of pathogens in health care environments. Future research studies should evaluate strategies to improve glove use to reduce HAIs.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.