Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

An electronic trigger based on care escalation to identify preventable adverse events in hospitalised patients.

Bhise V, Sittig DF, Vaghani V, Wei L, Baldwin J, Singh H. An electronic trigger based on care escalation to identify preventable adverse events in hospitalised patients. BMJ quality & safety. 2018 Mar 1; 27(3):241-246.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

BACKGROUND: Methods to identify preventable adverse events typically have low yield and efficiency. We refined the methods of Institute of Healthcare Improvement's Global Trigger Tool (GTT) application and leveraged electronic health record (EHR) data to improve detection of preventable adverse events, including diagnostic errors. METHODS: We queried the EHR data repository of a large health system to identify an 'index hospitalization' associated with care escalation (defined as transfer to the intensive care unit (ICU) or initiation of rapid response team (RRT) within 15 days of admission) between March 2010 and August 2015. To enrich the record review sample with unexpected events, we used EHR clinical data to modify the GTT algorithm and limited eligible patients to those at risk for care escalation based on younger age and presence of minimal comorbid conditions. We modified the GTT review methodology; two physicians independently reviewed eligible 'e-trigger' positive records to identify preventable diagnostic and care management events. RESULTS: Of 88?428 hospitalisations, 887 were associated with care escalation (712 ICU transfers and 175 RRTs), of which 92 were flagged as trigger-positive and reviewed. Preventable adverse events were detected in 41 cases, yielding a trigger positive predictive value of 44.6% (reviewer agreement 79.35%; Cohen's kappa 0.573). We identified 7 (7.6%) diagnostic errors and 34 (37.0%) care management-related events: 24 (26.1%) adverse drug events, 4 (4.3%) patient falls, 4 (4.3%) procedure-related complications and 2 (2.2%) hospital-associated infections. In most events (73.1%), there was potential for temporary harm. CONCLUSION: We developed an approach using an EHR data-based trigger and modified review process to efficiently identify hospitalised patients with preventable adverse events, including diagnostic errors. Such e-triggers can help overcome limitations of currently available methods to detect preventable harm in hospitalised patients.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.