skip to page content
Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Detection and Remediation of Misidentification Errors in Radiology Examination Ordering.

Sheehan SE, Safdar N, Singh H, Sittig DF, Bruno MA, Keller K, Kinnard S, Brunner MC. Detection and Remediation of Misidentification Errors in Radiology Examination Ordering. Applied clinical informatics. 2020 Jan 29; 11(1):79-87.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

BACKGROUND: Despite progress in patient safety, misidentification errors in radiology such as ordering imaging on the wrong anatomic side persist. If undetected, these errors can cause patient harm for multiple reasons, in addition to producing erroneous electronic health records (EHR) data. OBJECTIVES: We describe the pilot testing of a quality improvement methodology using electronic trigger tools and preimaging checklists to detect "wrong-side" misidentification errors in radiology examination ordering, and to measure staff adherence to departmental policy in error remediation. METHODS: We retrospectively applied and compared two methods for the detection of "wrong-side" misidentification errors among a cohort of all imaging studies ordered during a 1-year period (June 1, 2015-May 31, 2016) at our tertiary care hospital. Our methods included: (1) manual review of internal quality improvement spreadsheet records arising from the prospective performance of preimaging safety checklists, and (2) automated error detection via the development and validation of an electronic trigger tool which identified discrepant side indications within EHR imaging orders. RESULTS: Our combined methods detected misidentification errors in 6.5/1,000 of study cohort imaging orders. Our trigger tool retrospectively identified substantially more misidentification errors than were detected prospectively during preimaging checklist performance, with a high positive predictive value (PPV: 88.4%, 95% confidence interval: 85.4-91.4). However, two third of errors detected during checklist performance were not detected by the trigger tool, and checklist-detected errors were more often appropriately resolved (? < 0.00001, 95% confidence interval: 2.0-6.9; odds ratio: 3.6). CONCLUSION: Our trigger tool enabled the detection of substantially more imaging ordering misidentification errors than preimaging safety checklists alone, with a high PPV. Many errors were only detected by the preimaging checklist; however, suggesting that additional trigger tools may need to be developed and used in conjunction with checklist-based methods to ensure patient safety.





Questions about the HSR website? Email the Web Team