Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Temperature Screening for SARS-CoV-2 in Nursing Homes: Evidence from Two National Cohorts.

McConeghy KW, White E, Panagiotou OA, Santostefano C, Halladay C, Feifer RA, Blackman C, Rudolph JL, Mor V, Gravenstein S. Temperature Screening for SARS-CoV-2 in Nursing Homes: Evidence from Two National Cohorts. Journal of the American Geriatrics Society. 2020 Dec 1; 68(12):2716-2720.

Related HSR&D Project(s)

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

BACKGROUND/OBJECTIVES: Infection screening tools classically define fever as 38.0°C (100.4°F). Frail older adults may not mount the same febrile response to systemic infection as younger or healthier individuals. We evaluate temperature trends among nursing home (NH) residents undergoing diagnostic SARS-CoV-2 testing and describe the diagnostic accuracy of temperature measurements for predicting test-confirmed SARS-CoV-2 infection. DESIGN: Retrospective cohort study evaluating diagnostic accuracy of pre-SARS-CoV-2 testing temperature changes. SETTING: Two separate NH cohorts tested diagnostically (e.g., for symptoms) for SARS-CoV-2. PARTICIPANTS Veterans residing in Veterans Affairs (VA) managed NHs and residents in a private national chain of community NHs. MEASUREMENTS: For both cohorts, we determined the sensitivity, specificity, and Youden's index with different temperature cutoffs for SARS-CoV-2 polymerase chain reaction results. RESULTS: The VA cohort consisted of 1,301 residents in 134 facilities from March 1, 2020, to May 14, 2020, with 25% confirmed for SARS-CoV-2. The community cohort included 3,368 residents spread across 282 facilities from February 18, 2020, to June 9, 2020, and 42% were confirmed for SARS-CoV-2. The VA cohort was younger, less White, and mostly male. A temperature testing threshold of 37.2°C has better sensitivity for SARS-CoV-2, 76% and 34% in the VA and community NH, respectively, versus 38.0°C with 43% and 12% sensitivity, respectively. CONCLUSION: A definition of 38.0°C for fever in NH screening tools should be lowered to improve predictive accuracy for SARS-CoV-2 infection. Stakeholders should carefully consider the impact of adopting lower testing thresholds on testing availability, cost, and burden on staff and residents. Temperatures alone have relatively low sensitivity/specificity, and we advocate any threshold be used as part of a screening tool, along with other signs and symptoms of infection.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.