Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Development and validation of a new ICD-10-based screening colonoscopy overuse measure in a large integrated healthcare system: a retrospective observational study.

Adams MA, Kerr EA, Dominitz JA, Gao Y, Yankey N, May FP, Mafi J, Saini SD. Development and validation of a new ICD-10-based screening colonoscopy overuse measure in a large integrated healthcare system: a retrospective observational study. BMJ quality & safety. 2023 Jul 1; 32(7):414-424.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

BACKGROUND: Low-value use of screening colonoscopy is wasteful and potentially harmful to patients. Decreasing low-value colonoscopy prevents procedural complications, saves patient time and reduces patient discomfort, and can improve access by reducing procedural demand. The objective of this study was to develop and validate an electronic measure of screening colonoscopy overuse using International Classification of Diseases, Tenth Edition codes and then apply this measure to estimate facility-level overuse to target quality improvement initiatives to reduce overuse in a large integrated healthcare system. METHODS: Retrospective national observational study of US Veterans undergoing screening colonoscopy at 119 Veterans Health Administration (VHA) endoscopy facilities in 2017. A measure of screening colonoscopy overuse was specified by an expert workgroup, and electronic approximation of the measure numerator and denominator was performed ('electronic measure'). The electronic measure was then validated via manual record review (n = 511). Reliability statistics (n = 100) were calculated along with diagnostic test characteristics of the electronic measure. The measure was then applied to estimate overall rates of overuse and facility-level variation in overuse among all eligible patients. RESULTS: The electronic measure had high specificity (99%) and moderate sensitivity (46%). Adjusted positive predictive value and negative predictive value were 33% and 95%, respectively. Inter-rater reliability testing revealed near perfect agreement between raters (k = 0.81). 269 572 colonoscopies were performed in VHA in 2017 (88 143 classified as screening procedures). Applying the measure to these 88 143 screening colonoscopies, 24.5% were identified as potential overuse. Median facility-level overuse was 22.5%, with substantial variability across facilities (IQR 19.1%-27.0%). CONCLUSIONS: An International Classification of Diseases, Tenth Edition based electronic measure of screening colonoscopy overuse has high specificity and improved sensitivity compared with a previous International Classification of Diseases, Ninth Edition based measure. Despite increased focus on reducing low-value care and improving access, a quarter of VHA screening colonoscopies in 2017 were identified as potential low-value procedures, with substantial facility-level variability.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.