Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Comparison of virus aerosol concentrations across a face shield worn on a healthcare personnel during a simulated patient cough.

Pratt AA, Brown GD, Perencevich EN, Diekema DJ, Nonnenmann MW. Comparison of virus aerosol concentrations across a face shield worn on a healthcare personnel during a simulated patient cough. Infection control and hospital epidemiology. 2024 Feb 1; 45(2):221-226.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

BACKGROUND: Patients diagnosed with coronavirus disease 2019 (COVID-19) aerosolize severe acute respiratory coronavirus virus 2 (SARS-CoV-2) via respiratory efforts, expose, and possibly infect healthcare personnel (HCP). To prevent transmission of SARS-CoV-2 HCP have been required to wear personal protective equipment (PPE) during patient care. Early in the COVID-19 pandemic, face shields were used as an approach to control HCP exposure to SARS-CoV-2, including eye protection. METHODS: An MS2 bacteriophage was used as a surrogate for SARS-CoV-2 and was aerosolized using a coughing machine. A simulated HCP wearing a disposable plastic face shield was placed 0.41 m (16 inches) away from the coughing machine. The aerosolized virus was sampled using SKC biosamplers on the inside (near the mouth of the simulated HCP) and the outside of the face shield. The aerosolized virus collected by the SKC Biosampler was analyzed using a viability assay. Optical particle counters (OPCs) were placed next to the biosamplers to measure the particle concentration. RESULTS: There was a statistically significant reduction ( < .0006) in viable virus concentration on the inside of the face shield compared to the outside of the face shield. The particle concentration was significantly lower on the inside of the face shield compared to the outside of the face shield for 12 of the 16 particle sizes measured ( < .05). CONCLUSIONS: Reductions in virus and particle concentrations were observed on the inside of the face shield; however, viable virus was measured on the inside of the face shield, in the breathing zone of the HCP. Therefore, other exposure control methods need to be used to prevent transmission from virus aerosol.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.