Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Blood pressure measurement and blood pressure control in Veterans Affairs medical centers.

Halloran MO, Hughes AM, Huo Z, Weaver F, Stroupe K, Tarlov E, Kramer H. Blood pressure measurement and blood pressure control in Veterans Affairs medical centers. Journal of clinical hypertension (Greenwich, Conn.). 2023 Jul 1; 25(7):601-609.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

The Veterans Affairs (VA) medical centers provide care for millions of Veterans at high risk of cardiovascular disease and accurate BP measurement in this population is vital for optimal BP control. Few studies have examined terminal digit preference (TDP), a marker of BP measurement bias, clinician perceptions of BP measurement, and BP control in VA medical centers. This mixed methods study examined BP measurements from Veterans aged 18 to 85 years with hypertension and a primary care visit within 8 VA medical centers. TDP for all clinic BP measurements was examined using a goodness of fit test assuming 10% frequency for each digit. Interviews were also conducted with clinicians from 3 VA medical centers to assess perceptions of BP measurement. The mean age of the 98,433 Veterans (93% male) was 68.5 years (SD 12.7). BP was controlled ( < 140/90 mmHg) in 76.5% and control rates ranged from 72.2% to 81.0% across the 8 VA medical centers. Frequency of terminal digits 0 through 9 differed significantly from 10% for both SBP and DBP within each center (P  <  .001) but level of TDP differed by center. The highest BP control rates were noted in centers with highest TDP for digits 0 and 8 for both SBP and DBP. Clinicians reported use of semi-automated oscillometric devices for clinic BP measurement, but elevated BP readings were often confirmed by auscultatory methods. Significant TDP exists for BP measurement in VA medical centers, which reflects continued use of auscultatory methods.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.