Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Reliability of physical performance measures in nursing home residents with Alzheimer's disease.

Tappen RM, Roach KE, Buchner D, Barry C, Edelstein J. Reliability of physical performance measures in nursing home residents with Alzheimer's disease. The journals of gerontology. Series A, Biological sciences and medical sciences. 1997 Jan 1; 52(1):M52-5.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

BACKGROUND: Investigation of the effects of exercise on frail, institutionalized individuals with dementia has been impeded by concerns about the reliability of physical performance measures when used in this population. METHODS: The physical performance of 33 institutionalized subjects with Alzheimer's disease was measured during both the morning and afternoon of day 1 by rater 1 and during both the morning and afternoon of day 2, one week later, by rater 1 and rater 2. Intraclass correlation coefficients (ICCs) were calculated to examine the inter- and intrarater reliability of "sit to stand," "25-foot walk," and "the distance walked in 6 minutes" and walking speed over 25 feet and for 6 minutes. An analysis of variance was performed to determine the components of variance for each test. RESULTS: ICCs for "distance walked in 6 minutes" ranged from .80 to .99 with 77% of the variance explained by inter-subject difference. The ICCs for "time to walk 25 feet" ranged from .57 to .97 with 25% of the variance explained by inter-subject differences. In contrast, the "sit to stand" measure produced ICCs ranging from -.07 to .85 with only 7% of the variance explained by inter-subject differences in this impaired population. CONCLUSION: Our results support the contention that some physical performance measures can be used to test individuals in the later stages of Alzheimer's disease given appropriate modification. Although subjects with Alzheimer's disease may have difficulty following commands and/or require physical assistance, this does not prohibit the reliable assessment of physical performance if measurements are made over longer (6-minute walk) rather than shorter periods (25-foot walk).





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.