Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Evaluation of a generalizable approach to clinical information retrieval using the automated retrieval console (ARC).

D'Avolio LW, Nguyen TM, Farwell WR, Chen Y, Fitzmeyer F, Harris OM, Fiore LD. Evaluation of a generalizable approach to clinical information retrieval using the automated retrieval console (ARC). Journal of the American Medical Informatics Association : JAMIA. 2010 Jul 1; 17(4):375-82.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

Reducing custom software development effort is an important goal in information retrieval (IR). This study evaluated a generalizable approach involving with no custom software or rules development. The study used documents "consistent with cancer" to evaluate system performance in the domains of colorectal (CRC), prostate (PC), and lung (LC) cancer. Using an end-user-supplied reference set, the automated retrieval console (ARC) iteratively calculated performance of combinations of natural language processing-derived features and supervised classification algorithms. Training and testing involved 10-fold cross-validation for three sets of 500 documents each. Performance metrics included recall, precision, and F-measure. Annotation time for five physicians was also measured. Top performing algorithms had recall, precision, and F-measure values as follows: for CRC, 0.90, 0.92, and 0.89, respectively; for PC, 0.97, 0.95, and 0.94; and for LC, 0.76, 0.80, and 0.75. In all but one case, conditional random fields outperformed maximum entropy-based classifiers. Algorithms had good performance without custom code or rules development, but performance varied by specific application.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.