Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Detecting patient safety indicators: How valid is "foreign body left during procedure" in the Veterans Health Administration?

Chen Q, Rosen AK, Cevasco M, Shin M, Itani KM, Borzecki AM. Detecting patient safety indicators: How valid is "foreign body left during procedure" in the Veterans Health Administration? Journal of the American College of Surgeons. 2011 Jun 1; 212(6):977-83.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

BACKGROUND: The Agency for Healthcare Research and Quality (AHRQ) developed patient safety indicator (PSI) 5, "Foreign body left during procedure," to flag accidental foreign bodies in surgical and medical procedures. This study examined how well this indicator identifies true foreign body events in the Veterans Health Administration (VA). STUDY DESIGN: This was a retrospective study within 28 selected VA hospitals from fiscal year 2003 to 2007. Trained abstractors reviewed medical charts flagged by PSI 5 and determined true foreign body cases. We calculated the positive predictive value (PPV) of this indicator and performed descriptive analyses of true positive and false positive cases. RESULTS: Of the 652,093 eligible cases, 93 were flagged by PSI 5 (0.14 per 1,000). Forty-two were true positives, yielding a PPV of 45% (95% CI 35% to 56%). False positives were due to a foreign body that was present on admission (57%) or coding errors (43%). True foreign bodies were associated with surgical (n = 23) and medical (n = 19) procedures. The most common type of surgical foreign body was a sponge (52%). Overall, approximately 40% of foreign bodies were related to a device failure or malfunction (30% surgical vs 53% medical foreign bodies). Postoperative complications included pain (24%), infection (12%), adhesions (5%), and bowel obstruction (5%). CONCLUSIONS: The reported rate of foreign body events as detected by PSI 5 is low in the VA, but occurs in both surgical and medical procedures. Despite widespread implementation of surgical counts, quality improvement efforts should focus on novel ways to eliminate this "never event" from operations. Future studies are needed to better understand the preventability of medical procedure-associated foreign bodies and particularly, device failure-related foreign bodies.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.