Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Automated extraction of ejection fraction for quality measurement using regular expressions in Unstructured Information Management Architecture (UIMA) for heart failure.

Garvin JH, DuVall SL, South BR, Bray BE, Bolton D, Heavirland J, Pickard S, Heidenreich P, Shen S, Weir C, Samore M, Goldstein MK. Automated extraction of ejection fraction for quality measurement using regular expressions in Unstructured Information Management Architecture (UIMA) for heart failure. Journal of the American Medical Informatics Association : JAMIA. 2012 Sep 1; 19(5):859-66.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

OBJECTIVES: Left ventricular ejection fraction (EF) is a key component of heart failure quality measures used within the Department of Veteran Affairs (VA). Our goals were to build a natural language processing system to extract the EF from free-text echocardiogram reports to automate measurement reporting and to validate the accuracy of the system using a comparison reference standard developed through human review. This project was a Translational Use Case Project within the VA Consortium for Healthcare Informatics. MATERIALS AND METHODS: We created a set of regular expressions and rules to capture the EF using a random sample of 765 echocardiograms from seven VA medical centers. The documents were randomly assigned to two sets: a set of 275 used for training and a second set of 490 used for testing and validation. To establish the reference standard, two independent reviewers annotated all documents in both sets; a third reviewer adjudicated disagreements. RESULTS: System test results for document-level classification of EF of < 40% had a sensitivity (recall) of 98.41%, a specificity of 100%, a positive predictive value (precision) of 100%, and an F measure of 99.2%. System test results at the concept level had a sensitivity of 88.9% (95% CI 87.7% to 90.0%), a positive predictive value of 95% (95% CI 94.2% to 95.9%), and an F measure of 91.9% (95% CI 91.2% to 92.7%). DISCUSSION: An EF value of < 40% can be accurately identified in VA echocardiogram reports. CONCLUSIONS: An automated information extraction system can be used to accurately extract EF for quality measurement.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.