Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Validity of self-report measures in assessing antiretroviral adherence of newly diagnosed, HAART-naïve, HIV patients.

Buscher A, Hartman C, Kallen MA, Giordano TP. Validity of self-report measures in assessing antiretroviral adherence of newly diagnosed, HAART-naïve, HIV patients. HIV Clinical Trials. 2011 Sep 1; 12(5):244-54.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

Purpose: To compare the performance of self-report instruments assessing adherence to antiretroviral therapy (ART) in patients starting ART for the first time and in a predominately Hispanic population.Methods: Of 184 patients in a prospective observational cohort study of newly diagnosed, minority patients of low socioeconomic status, 54 were given Medication Event Monitoring System (MEMS) caps for their boosted protease inhibitor (PI) or non-nucleoside reverse transcriptase inhibitor (NNRTI). They completed a 4-week recall visual analogue scale (VAS), the Adult AIDS Clinical Trial Group (AACTG) 4-day recall instrument, and a 1-month recall qualitative single-item measure every 3 months for up to 18 months in English or Spanish. Electronic pharmacy records recorded refill dates. Spearman correlation coefficients were calculated to compare self-report measures with MEMS data and pharmacy data.Results: Of 46 patients with MEMS data, mean adherence was 84.7% (SD 35.6) by MEMS, 84.5% (SD 15.1) by pharmacy, 95.4% (SD 11.9) by VAS, 95.8% (SD 17.2) by AACTG, and 87.6% (SD 28.2) by qualitative single item. The correlation coefficient (CC) of VAS with MEMS was 0.37 (P < .01), and with pharmacy it was 0.34 (P < .01). The CC of the AACTG with MEMS was 0.32 (P < .01), and with pharmacy it was 0.28 (P < .01). The qualitative single item had a CC with MEMS of 0.24 (P < .01) and with pharmacy of 0.32 (P < .01). Spanish-speaking patients' VAS adherence had a CC of 0.40 (P < .01) with MEMS.Conclusions: The VAS, AACTG, and qualitative single-item measures correlated significantly with MEMS and pharmacy data. Our data support self-administration of the VAS, even in Span-ish speakers.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.