Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Automated concept-level information extraction to reduce the need for custom software and rules development.

D'Avolio LW, Nguyen TM, Goryachev S, Fiore LD. Automated concept-level information extraction to reduce the need for custom software and rules development. Journal of the American Medical Informatics Association : JAMIA. 2011 Sep 1; 18(5):607-13.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

OBJECTIVE: Despite at least 40 years of promising empirical performance, very few clinical natural language processing (NLP) or information extraction systems currently contribute to medical science or care. The authors address this gap by reducing the need for custom software and rules development with a graphical user interface-driven, highly generalizable approach to concept-level retrieval. MATERIALS AND METHODS: A 'learn by example' approach combines features derived from open-source NLP pipelines with open-source machine learning classifiers to automatically and iteratively evaluate top-performing configurations. The Fourth i2b2/VA Shared Task Challenge's concept extraction task provided the data sets and metrics used to evaluate performance. RESULTS: Top F-measure scores for each of the tasks were medical problems (0.83), treatments (0.82), and tests (0.83). Recall lagged precision in all experiments. Precision was near or above 0.90 in all tasks. Discussion With no customization for the tasks and less than 5andemsp14;min of end-user time to configure and launch each experiment, the average F-measure was 0.83, one point behind the mean F-measure of the 22 entrants in the competition. Strong precision scores indicate the potential of applying the approach for more specific clinical information extraction tasks. There was not one best configuration, supporting an iterative approach to model creation. CONCLUSION: Acceptable levels of performance can be achieved using fully automated and generalizable approaches to concept-level information extraction. The described implementation and related documentation is available for download.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.