Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Quantitating physical activity in COPD using a triaxial accelerometer.

Steele BG, Holt L, Belza B, Ferris S, Lakshminaryan S, Buchner DM. Quantitating physical activity in COPD using a triaxial accelerometer. Chest. 2000 May 1; 117(5):1359-67.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

STUDY OBJECTIVE: To determine the reliability, validity, and stability of a triaxial accelerometer for walking and daily activity measurement in a COPD sample. DESIGN: Cross-sectional, correlational, descriptive design. SETTING: Outpatient pulmonary rehabilitation program in a university-affiliated Veterans Affairs medical center. PARTICIPANTS: Forty-seven outpatients (44 men and 3 women) with stable COPD (FEV(1), 37% predicted; SD, 16%) prior to entry into a pulmonary rehabilitation program. MEASUREMENTS AND RESULTS: Test-retest reliability of a triaxial movement sensor (Tritrac R3D Research Ergometer; Professional Products; Madison, WI) was evaluated in 35 of the 47 subjects during three standardized 6-min walks (intraclass correlation coefficient [rICC] = 0.84). Pearson correlations evaluated accelerometer concurrent validity as a measure of walking (in vector magnitude units), compared to walking distance in all 47 subjects during three sequential 6-min walks (0. 84, 0.85, and 0.95, respectively; p < 0.001). The validity of the accelerometer as a measure of daily activity over 3 full days at home was evaluated in all subjects using Pearson correlations with other indicators of functional capacity. The accelerometer correlated with exercise capacity (maximal 6-min walk, r = 0.74; p < 0.001); level of obstructive disease (FEV(1) percent predicted, r = 0.62; p < 0.001); dyspnea (Functional Status and Dyspnea Questionnaire, dyspnea over the past 30 days, r = - 0.29; p < 0.05); and activity self-efficacy (Activity Self-Efficacy Questionnaire, r = 0.43; p < 0.01); but not with self-report of daily activity (Modified Activity Recall Questionnaire, r = 0.14; not significant). Stability of the accelerometer to measure 3 full days of activity at home was determined by an rICC of 0.69. CONCLUSIONS: This study provides preliminary data suggesting that a triaxial movement sensor is a reliable, valid, and stable measure of walking and daily physical activity in COPD patients. It has the potential to provide more precise measurement of everyday physical functioning in this population than self-report measures currently in use, and measures an important dimension of functional status not previously well-described.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.