Cost-effectiveness of automated external defibrillator deployment in selected public locations.

Cram P, Vijan S, Fendrick AM. Cost-effectiveness of automated external defibrillator deployment in selected public locations. Journal of general internal medicine. 2003 Sep 1; 18(9):745-54.

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

OBJECTIVE: The American Heart Association (AHA) recommends an automated external defibrillator (AED) be considered for a specific location if there is at least a 20% annual probability the device will be used. We sought to evaluate the cost-effectiveness of the AHA recommendation and of AED deployment in selected public locations with known cardiac arrest rates. DESIGN: Markov Decision Model employing a societal perspective. SETTING: Selected public locations in the United States. PATIENTS: A simulated cohort of the American public. INTERVENTION: Strategy 1: individuals experiencing cardiac arrest were treated by emergency medical services equipped with AEDs (EMS-D). Strategy 2: individuals were treated with AEDs deployed as part of a public access defibrillation program. Strategies differed only in the initial availability of an AED and its impact on cardiac arrest survival. RESULTS: Under the base-case assumption that a deployed AED will be used on 1 cardiac arrest every 5 years (20% annual probability of AED use), the cost per quality-adjusted life year (QALY) gained is $30,000 for AED deployment compared with EMS-D care. AED deployment costs less than $50,000 per QALY gained provided that the annual probability of AED use is 12% or greater. Monte Carlo simulation conducted while holding the annual probability of AED use at 20% demonstrated that 87% of the trials had a cost-effectiveness ratio of less than $50,000 per QALY. CONCLUSIONS: AED deployment is likely to be cost-effective across a range of public locations. The current AHA guidelines are overly restrictive. Limited expansion of these programs can be justified on clinical and economic grounds.





Questions about the HSR website? Email the Web Team