Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR&D Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Validation of a short version of the glaucoma medication self-efficacy questionnaire.

Sleath B, Blalock SJ, Stone JL, Skinner AC, Covert D, Muir K, Robin AL. Validation of a short version of the glaucoma medication self-efficacy questionnaire. The British journal of ophthalmology. 2012 Feb 1; 96(2):258-62.

Related HSR&D Project(s)

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

AIMS: The aims of this study were: (1) to examine whether the original glaucoma medication adherence and eye drop technique self-efficacy scales could be shortened for easier use in practice settings; and (2) to validate these scales against objective medication adherence measures. METHODS: Prospective study conducted at a single private practice site. We measured subjects'' adherence to glaucoma medications through Medication Event Monitoring System (MEMS) devices and assessed eye drop instillation technique by video-recording. Principal components factor analysis and logistic and linear regression were used to analyse the data. RESULTS: Our results yielded a 10-item Glaucoma Medication Adherence Self-Efficacy Scale that was strongly associated with subject adherence measured using MEMS (ß coefficient 8.52, 95% CI 1.94 to 15.1). In addition, the six-item Eye Drop Technique Self-Efficacy Scale was strongly associated with video-recorded subject eye drop installation technique (OR 10.47, 95% CI 1.78 to 61.63). CONCLUSIONS: Eye care providers and researchers could use these shorter scales to identify subjects with either poor glaucoma medication adherence and/or eye drop instillation technique. This could help to identify those who may benefit most from education and training on both adherence and eye drop instillation.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.