Talk to the Veterans Crisis Line now
U.S. flag
An official website of the United States government

VA Health Systems Research

Go to the VA ORD website
Go to the QUERI website

HSR Citation Abstract

Search | Search by Center | Search by Source | Keywords in Title

Incidence and clinical predictors of low defibrillation safety margin at time of implantable defibrillator implantation.

Cheng Z, Turakhia M, Lo R, Gupta A, Zei PC, Hsia HH, Al-Ahmad A, Wang PJ. Incidence and clinical predictors of low defibrillation safety margin at time of implantable defibrillator implantation. Journal of Interventional Cardiac Electrophysiology. 2012 Jun 1; 34(1):93-100.

Related HSR&D Project(s)

Dimensions for VA is a web-based tool available to VA staff that enables detailed searches of published research and research projects.

If you have VA-Intranet access, click here for more information vaww.hsrd.research.va.gov/dimensions/

VA staff not currently on the VA network can access Dimensions by registering for an account using their VA email address.
   Search Dimensions for VA for this citation
* Don't have VA-internal network access or a VA email address? Try searching the free-to-the-public version of Dimensions



Abstract:

BACKGROUND: Determination of the defibrillation safety margin (DSM) is the most common method of testing device effectiveness at the time of implantation of implantable cardioverter defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRTD). Low DSM remains a problem in clinical practice. OBJECTIVE: The purpose of this study is to ascertain the incidence and clinical predictors of low DSM and the treatment strategies for low DSM in ICD or CRTD recipients. METHODS: Selected ICD or CRTD recipients from January 2006 to May 2008 who underwent DSM test at the time of implantation were included. Low DSM patients were defined as patients who had a DSM within 10 J of the maximum delivered energy of the device. These patients were compared to patients who had DSM? > 10 J. RESULTS: This study included 243 patients. Of these, 13 (5.3%) patients had low DSM, and 230 patients had adequate DSM. Patients with low DSM had a high prevalence of amiodarone use (69% vs 13%, p? < 0.01), secondary prevention indications (69% vs 30%, p? < 0.01), and a trend toward younger age (51? ?18 vs 58? ?15 years, p? = 0.08). After adjustment for age and sex, amiodarone use was significantly associated with low DSM. All low DSM patients except one obtained adequate DSM after taking additional steps, including discontinuing amiodarone and starting sotalol, RV lead repositioning, adding a subcutaneous array or shock coil, changing single-coil to dual-coil lead, and upgrading to a high output device. CONCLUSION: The incidence of low DSM patients is low with high-energy devices. Amiodarone use is associated with low DSM, and its discontinuation or substitution with sotalol is one of a variety of available options for low DSM patients.





Questions about the HSR website? Email the Web Team

Any health information on this website is strictly for informational purposes and is not intended as medical advice. It should not be used to diagnose or treat any condition.